product-spec drifast-sealer application.temperature_range_c

What temperature range can Bona DriFast Sealer be applied at?

18-27 C (absolute minimum use: 16 C)

Apply Bona DriFast Sealer at 18-27 C (absolute minimum use: 16 C). Temperature affects recoat window, sheen uniformity and intercoat adhesion. Below the minimum use temperature the film will not coalesce properly; above the maximum, applicator drag marks and rapid surface skinning increase risk of sheen variation. Site conditions (slab temperature, direct sun) matter as much as air temperature — mask windows to avoid direct sun during application and early drying.

Sources