Entwicklungs- und Prueflabor Holztechnologie GmbH • Zellescher Weg 24 • 01217 Dresden • Germany Bona AB Entwicklungs- und Prueflabor Holztechnologie GmbH Mr. Patrik Mellnert Zellescher Weg 24 Murmansgatan 130 Box 210 74 01217 Dresden • Germany 200 21 Malmö Rhone:+49 3514662 0 Schweden Fax:+49 3514662 211 info@eph-dresden.de www.eph-dresden.de E-Mail: Patrik.Mellnert@bona.com Sw-50 Dresden, 19 October, 2018 Test Report Order no.2518463 Client: Bona AB Murmansgatan 130 Box 210 74 200 21 Malmö Schweden Date of order: 24 September, 2018 Order: Determination of the migration behavior of heavy metals according to DIN EN 71-3: 2018-08 (category III, table 1) in 4 samples Contractor: EPH - Laboratory Chemical testing Engineer in Charge: Dr. Christiane Swaboda Prof. Dr. habil. M. Beyer Head of Laboratory Chemical Testing The test report contains 4 pages. Any duplication, even in part, requires written permission of EPH. These test results are exclusively related to the tested materials Managing Director: Commerzbank AG Deutsches Dr.-Ing. Rico Emmler Dresden Local Court HRB 8072 SWIFT: DRES DE FF 850 IBAN: DE 13 8508 0000 0400 2982 00 (( DAkkS D-W.-UOWJ1-00 Institut Bautechnik für DIBt Europäisch notiflrlerte Stelle für Bau ro uVte 0766 VAT Reg. No. DE 2160 77 44 6 Bauaufslchtllch an rkannte Stell des DIBt SAC03 Page 2 of 4 of Test Report, order no. 2518463 dated 19 October, 2018 1 Assignment Determination of the migration behaviour of heavy metals according to DIN EN 71-3 (category III, table 1) in 4 variants of lacquers. 2 Sample material The dient handed over the following samples: PI WT 3006 Mega ONE P2 341-86N Bona Pure P3 341-86P Bona LinoPrime P4 341-86R Bona Pure Colour Sample receipt in the EPH: 25 September 2018 The test material is stored for 3 months. 3 Investigations carried out 3.1 Migration behavior of heavy metals acc. to DI EN 71-3 The following elements were to be determined: Aluminum (AI), Antimony (Sb), Arsenic (As), Barium (Ba), Boron (B), Cadmium (Cd), Cobalt (Co), Chrome (Cr), Copper (Cu), Mercury (Hg), Manganese (Mn), Nickel (Ni), Lead (Pb), Selenium (Se), Tin (Sn), Strontium (Sr), Zinc (Zn) About 1 g of the lacquer were scraped from the surface of the glass plates added with 50 ml of 0.07 mol HCl, stirred for 15 minutes at 37°C and then left for 2 hours. Afterwards, the liquid was separated by centrifugation. The resulting pH - value of the Solutions was 1.5. The quantitative determination of the heavy metals was carried out with the methods and detection limits indicated in table 1. The results are average values from a double determination. The evaluation of the results followed the limit values for category III according to pt. 4.2 for scratched materials. Table 1 Methods, determination limits and limit values for estimation of the heavy metal contents Element AI As Ba B Cd Co Cr Cu Method ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES Wavelength 213.598 237.312 193.696 455.403 182.577 214.439 230.786 205.560 [nm] DL 0.05 0.1 3.0 1.5 0.1 3.0 0.05 0.1 [mg/kg] LV category IN 460 70000 47 18750 15000 17 130 7700 0.2* [mg/kg] Page 3 of 4 of Test Report, order no. 2518463 dated 19 October, 2018 Continuation of table 1 Element Hg Mn Ni Pb Sb Se Sn Sr Zn ICP-OES Method with ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES ICP-OES Hydrid Wavelength 257.610 231.604 220.353 206.834 196.026 189.925 407.771 213.857 Systeme [nm] 184.887 DL 0.05 1.5 0.05 0.05 0.3 1.5 1.5 1.5 0.05 [mg/kg] LV category 180000 94 15000 930 23 560 460 • 2** 56000 46000 III [mg/kg] ICP-OES = Inductively Coupled Plasma Optical Emission Spectrometry, DL= Determination Limit LV = Limit value acc.to DIN EN 71-3. pt. 4.2 table 2 in connection with table 1 pt. 4.1 * vaiue for Cr VI ** = Value for Organotin 4 Results Table 2 Contents of heavy metals after extraction acc. to DIN EN 71-3 in mg/kg Sample AI As B Ba Cd Co Cr Cu PI 1.9 < DL 69.0 0.2 < DL 0.1 0.1 0.4 P2 2.3 < DL 5.8 0.5 < DL < DL 0.1 1.1 P3 9.7 < DL 8.3 0.9 < DL < DL 0.1 1.4 P4 32.7 < DL 3.9 0.4 < DL < DL 0.1 0.4 Continuation of table 2 Sample Hg Mn Ni Pb Sb Se Sn Sr Zn PI < DL < DL 0.7 0.3 < DL < DL 0.4 0.2 < DL P2 < DL < DL 0.2 0.4 < DL < DL 0.4 0.7 < DL P3 < DL < DL 0.8 13.3 < DL < DL 1.5 1.4 < DL P4 < DL < DL 0.4 1.6 < DL < DL < DL 0.4 < DL DL= Determination limit Page 4 of 4 of Test Report, Order no. 2518463 dated 19 October, 2018 5 Evaluation The 4 products completely meet the requirements of DIN E 71-3 (2018:08). 6 Miscellaneous The product samples will be stored in the EPH for 3 months as retained samples. Dr. rer. nat. Ch. Swaboda Chemist in Charge